提出利用电极片检测熔盐储罐泄漏的方法并实验研究其可行性。结果表明,不同温度的熔盐发生泄漏时,熔盐会使电极片的回路立即形成通路,从而灵敏地检测到熔盐储罐的泄漏。并且,熔盐的运行温度越高、电极片布置位置越靠近地基材料顶部,熔盐泄漏到电极片上时导电性越强,电路中的电流越大,电极片检测熔盐罐泄漏的灵敏性和持续性越好。
Abstract
This paper presents a method for detecting the leakage of molten salt tank by electrode slices and the feasibility of the method is studied experimentally. The results show that when molten salt at different temperatures leaks, it will make the circuit of the electrode slices immediately form a path, and the leakage of the molten salt tank can be sensitively detected. Besides, the higher the operating temperature of molten salt, the closer the electrode slices are to the top of the foundation material, the stronger the conductivity of molten salt reaching the electrode slices, the greater the current of the circuit, the better the sensitivity and continuity of the electrode slices to detect the leakage of molten salt tank.
关键词
太阳能热发电 /
熔盐罐 /
泄漏 /
导电性 /
电极片
Key words
solar thermal power generation /
molten salt tanks /
leakage /
electrical conductivity /
electrode slices
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] PRIETO C, OSUNA R, FERNÁNDEZ A I, et al. Molten salt facilities, lessons learnt at pilot plant scale to guarantee commercial plants; heat losses evaluation and correction[J]. Renewable energy, 2016, 94: 175-185.
[2] 崔杨, 杨志文, 严干贵, 等. 降低火电机组调峰成本的光热电站储热容量配置方法[J]. 中国电机工程学报, 2018, 38(6) : 1605-1611.
CUI Y, YANG Z W, YAN G G, et al.Capacity configuration of thermal energy storage within CSP to reduce the cost of peak load regulation[J]. Proceedings of the CSEE, 2018, 38(6): 1605-1611.
[3] HASNAIN S M.Review on sustainable thermal energy storage technologies, part I: heat storage materials and techniques[J]. Energy conversion and management, 1998, 39(11): 1127-1138.
[4] FLUECKIGER S, YANG Z, GARIMELLA S V.An integrated thermal and mechanical investigation of molten-salt thermocline energy storage[J]. Applied energy, 2011, 88(6): 2098-2105.
[5] GE Q, XIONG F, PENG X Y. Method study for finite element modeling of large oil storage tanks[J]. Applied mechanics and materials, 2012, 166-169: 471-476.
[6] WAN Z J Q, WEI J J Q, QAISRANI M Q, et al. Evaluation on thermal and mechanical performance of the hot tank in the two-tank molten salt heat storage system[J]. Applied thermal engineering, 2020, 167: 114775.
[7] WEISBROD N, NIEMET M R, ROCKHOLD M L, et al.Migration of saline solutions in variably saturated porous media[J]. Journal of contaminant hydrology, 2004, 72(1-4): 109-133.
[8] HIRD R, M D BOLTON. Migration of sodium chloride in dry porous materials[J]. Proceedings of the royal society a mathematical physical & engineering sciences, 2016, 472(2186): 20150710.
[9] YANG X P, YANG X X, QIN F G F, et al. Experimental investigation of a molten salt thermocline storage tank[J]. International journal of sustainable energy, 2016, 35(6): 606-614.
[10] YIN H B, DING J, JIANG R H, et al.Thermocline characteristics of molten-salt thermal energy storage in porous packed-bed tank[J]. Applied thermal engineering, 2017, 110: 855-863.
[11] LU J F, DING J, YANG J P.Solidification and melting behaviors and characteristics of molten salt in cold filling pipe[J]. International journal of heat mass transfer, 2010, 53(9-10): 1628-1635.
[12] LIAO Z R, LI X, WANG Z F, et al.Phase change of molten salt during the cold filling of a receiver tube[J]. Solar energy, 2014, 101: 254-264.
[13] ZHOU H, SHI H, LAI Z Y, et al.Migration and phase change study of leaking molten salt in tank foundation material[J]. Applied thermal engineering, 2020, 170: 114968.
[14] WU J Q, DING J, LU J F, et al.Migration and phase change phenomena and characteristics of molten salt leaked into soil porous system[J]. International journal of heat mass transfer, 2017, 111: 312-320.
[15] ZHANG Y Y, WU J Q, WANG W L, et al.Experimental and numerical studies on molten salt migration in porous system with phase change[J]. International journal of heat mass transfer, 2019, 129: 397-405.