基于LADRC和准PR的三相LCL型光伏并网逆变器谐波谐振抑制策略

周雪松, 郭帅朝, 马幼婕, 李月超, 马闯

太阳能学报 ›› 2023, Vol. 44 ›› Issue (3) : 465-474.

PDF(2697 KB)
欢迎访问《太阳能学报》官方网站,今天是
PDF(2697 KB)
太阳能学报 ›› 2023, Vol. 44 ›› Issue (3) : 465-474. DOI: 10.19912/j.0254-0096.tynxb.2021-1319

基于LADRC和准PR的三相LCL型光伏并网逆变器谐波谐振抑制策略

  • 周雪松, 郭帅朝, 马幼婕, 李月超, 马闯
作者信息 +

HARMONIC RESONANCE SUPPRESSION STRATEGY OF THREE-PHASE LCL PHOTOVOLTAIC GRID-CONNECTED INVERTER BASED ON LADRC AND QUASI PR

  • Zhou Xuesong, Guo Shuaichao, Ma Youjie, Li Yuechao, Ma Chuang
Author information +
文章历史 +

摘要

针对三相LCL型光伏并网逆变器由自身高频段谐振尖峰引起的谐波谐振现象,设计一种基于三阶线性状态观测器的二阶线性自抗扰控制(LADRC)和准PR控制相结合的电流双闭环控制策略,较好地削弱了高频段的谐振尖峰,抑制了光伏系统的谐波谐振现象。通过设计李雅普诺夫函数证明了闭环系统最终会稳定收敛;利用仿真对不同工况下的控制策略深入对比分析,结果表明此双环控制策略具有优越的鲁棒性和实际应用价值。

Abstract

Aiming at the harmonic resonance phenomenon of three-phase LCL photovoltaic grid connected inverter from its high frequency resonant peak, a current double closed loop control strategy based on third-order LESO combined with second-order LADRC and quasi PR control is designed. It can better weaken the high frequency resonant peak and suppress the harmonic resonance phenomenon of photovoltaic system. By designing Lyapunov function, it is proved that the closed-loop system will eventually converge stably. The simulation results show that the double loop control strategy has superior robustness and practical application value.

关键词

光伏系统 / LCL型逆变器 / 线性自抗扰 / 比例谐振控制 / 谐波谐振现象

Key words

PV system / LCL-type inverter / linear active disturbance rejection / proportional resonance control / harmonic resonance phenomenon

引用本文

导出引用
周雪松, 郭帅朝, 马幼婕, 李月超, 马闯. 基于LADRC和准PR的三相LCL型光伏并网逆变器谐波谐振抑制策略[J]. 太阳能学报. 2023, 44(3): 465-474 https://doi.org/10.19912/j.0254-0096.tynxb.2021-1319
Zhou Xuesong, Guo Shuaichao, Ma Youjie, Li Yuechao, Ma Chuang. HARMONIC RESONANCE SUPPRESSION STRATEGY OF THREE-PHASE LCL PHOTOVOLTAIC GRID-CONNECTED INVERTER BASED ON LADRC AND QUASI PR[J]. Acta Energiae Solaris Sinica. 2023, 44(3): 465-474 https://doi.org/10.19912/j.0254-0096.tynxb.2021-1319
中图分类号: TM464   

参考文献

[1] 周娟,徐高祥,钊翔坤,等. LCL型有源电力滤波器的强鲁棒性控制器优化设计[J]. 电力系统保护与控制,2022, 50(10): 140-152.
ZHOU J, XU G X, ZHAO X K, et al.Optimization design of strong robust controller for an LCL-type active power filter[J]. Power system protection and control, 2022, 50(10): 140-152.
[2] ZHOU W Y, WANG M Q, WU Q F.A model-based monitoring method for offline accelerated testing of DC-link capacitor in three-phase inverter systems[J]. IEEE transactions on power electronics, 2021, 36(1): 61-67.
[3] HOU X C, SUN K, ZHANG X, et al.A hybrid voltage/current control scheme with low-communication burden for grid-connected series-type inverters in decentralized manner[J]. IEEE transactions on power electronics, 2022,37(1): 920-931.
[4] XU H L, NIE F, WANG Z X, et al.Impedance modeling and stability factor assessment of grid-connected converters based on linear active disturbance rejection control[J]. Journal of modern power systems and clean energy, 2021, 9(6): 1327-1338.
[5] 杨林, 曾江, 黄仲龙. 线性自抗扰技术在LCL逆变器并网电流控制及有源阻尼中的应用[J]. 电网技术, 2019,43(4): 1378-1386.
YANG L, ZENG J, HUANG Z L.Application of linear active disturbance rejection technique in grid-connected current control and active damping of LCL type inverter[J].Power system technology, 2019, 43(4): 1378-1386.
[6] 朱良红, 张国强, 李宇欣, 等. 基于级联扩张观测器的永磁电机无传感器自抗扰控制策略[J]. 电工技术学报,2022, 37(18): 4614-4624.
ZHU L H, ZHANG G Q, LI Y X, et al.Active disturbance rejection control for position sensorless permanent magnet synchronous motor drives based on cascade extended state observer[J]. Transactions of China Electrotechnical Society, 2022, 37(18): 4614-4624.
[7] 高志强. 自抗扰控制思想探究[J]. 控制理论与应用, 2013, 30(12): 1498-1510.
GAO Z Q.On the foundation of active disturbance rejection control[J]. Control theory & applications, 2013,30(12): 1498-1510.
[8] LI P, WANG L, ZHU G L, et al.Predictive active disturbance rejection control for servo systems with communication delays via sliding mode approach[J]. IEEE transactions on industrial electronics,2021, 68(12):12679-12688.
[9] 宋国杰, 李国进, 杨浩, 等. 基于d-q坐标系下LCL型光伏并网逆变器的PI+状态反馈控制[J]. 太阳能学报,2020, 41(11): 135-142.
SONG G J, LI G J, YANG H, et al.PI+ state feedback controller of LCL single-phase PV grid-connected inverter based on d-q coordinate system[J]. Acta energiae solaris sinica,2020, 41(11): 135-142.
[10] ZUO Y F, MEI J, JIANG C Q, et al.Linear active disturbance rejection controllers for PMSM speed regulation system considering the speed filter[J]. IEEE transactions on power electronics,2021, 36(12): 14579-14592.
[11] 程启明, 叶培乐, 魏霖, 等. 电网不平衡条件下基于滑模控制TLDMC输入功率控制[J]. 高电压技术, 2021, 47(12): 4440-4450.
CHENG Q M,YE P L, WEI L, et al.Input power control of TLDMC based on sliding mode control under unbalanced grid voltage[J]. High voltage engineering, 2021, 47(12): 4440-4450.
[12] 刘聪, 李立生, 刘洋, 等. 基于准PR控制的锂电池储能并网系统功率控制[J]. 电测与仪表, 2021, 58(8): 172-178.
LIU C, LI L S, LIU Y, et al.Power control of lithium battery energy storage grid-connected system based on quasi-PR control[J]. Electrical measurement and instrumentation, 2021, 58(8): 172-178.
[13] LIN P, WU Z, FEI Z Y, et al.A generalized PID interpretation for high-order LADRC and cascade LADRC for servo systems[J]. IEEE transactions on industrial electronics, 2022, 69(5): 5207-5214.
[14] HAO Z J, YANG Y, GONG Y M, et al.Linear/nonlinear active disturbance rejection switching control for permanent magnet synchronous motors[J]. IEEE transactions on power electronics, 2021, 36(8): 9334-9347.

基金

国家自然科学基金面上项目(51877152)