摘要

提出一种基于多频段自适应陷波器(MANF)的风电外送系统SSO抑制策略。首先,在分析SSO产生机理的基础上确定MANF在双馈风电机组(DFIG)转子侧变流器(RSC)中的安装位置。其次,利用递归群谐波功率最小化(RGPM)算法优化的DFT辨识法设计次同步振荡检测器,有效解决模态混叠等问题;然后利用加窗稀疏度自适应匹配追踪(SAMP)算法,设计可根据输入频率实时更新陷波频率的MANF。最后,通过与多陷波点陷波器(MNF)和单陷波点自适应陷波器(ANF)对比,验证了抑制策略的有效性;在考虑不同串补度、风电部分切机同时火电补发功率的工况下,验证了抑制策略的鲁棒性。

Abstract

A sub-synchronous oscillation suppression strategy for wind power transmission systems based on multi band adaptive notch filter (MANF) is proposed. Firstly, based on the mechanism analysis of sub-synchronous oscillation, the installation position of MANF in the rotor measurement converter (RSC) of doubly fed induction generator (DFIG) is determined. Secondly, the DFT identification method optimized by the recursive group harmonic power minimization (RGPM) algorithm is used to design a sub-synchronous oscillation detector, effectively solving problems such as mode mixing. Then, using the windowed sparsity adaptive matching pursuit (SAMP) algorithm, design a MANF that can update the notch frequency in real time based on the input frequency. Finally, the effectiveness of the suppression strategy was verified by comparing with the multi notch notch filter (MNF) and the single notch adaptive notch filter (ANF). The robustness of the suppression strategy was verified under the conditions of considering different series compensation degrees, wind power partial cutting, and thermal power replenishment power.

关键词

风电机组 / 次同步振荡 / 电力系统稳定性 / 次同步振荡检测器 / 多频段自适应陷波器

Key words

wind turbines / sub-synchronous oscillation / power system stability / sub-synchronous oscillation detector / multi band adaptive notch filter

引用本文

导出引用
王子建, 谷瑞峰, 马燕峰, 张鑫宇, 赵书强. 基于多频段自适应陷波器的风电外送系统次同步振荡抑制策略[J]. 太阳能学报. 2024, 45(11): 141-152 https://doi.org/10.19912/j.0254-0096.tynxb.2023-1239
Wang Zijian, Gu Ruifeng, Ma Yanfeng, Zhang Xinyu, Zhao Shuqiang. SUB-SYNCHRONOUS OSCILLATION SUPPRESSION STRATEGY FOR WIND POWER TRANSMISSION SYSTEMS BASED ON MULTI BAND ADAPTIVE NOTCH FILTERS[J]. Acta Energiae Solaris Sinica. 2024, 45(11): 141-152 https://doi.org/10.19912/j.0254-0096.tynxb.2023-1239
中图分类号: TM712   

参考文献

[1] 马宁宁, 谢小荣, 贺静波, 等. 高比例新能源和电力电子设备电力系统的宽频振荡研究综述[J]. 中国电机工程学报, 2020, 40(15): 4719-4731.
MA N N, XIE X R, HE J B, et al.Review of wide-band oscillation in renewable and power electronics highly integrated power systems[J]. Proceedings of the CSEE, 2020, 40(15): 4719-4731.
[2] 肖湘宁, 罗超, 廖坤玉. 新能源电力系统次同步振荡问题研究综述[J]. 电工技术学报, 2017, 32(6): 85-97.
XIAO X N, LUO C, LIAO K Y.Review of the research on subsynchronous oscillation issues in electric power system with renewable energy sources[J]. Transactions of China Electrotechnical Society, 2017, 32(6): 85-97.
[3] 陈露洁, 徐式蕴, 孙华东, 等. 高比例电力电子电力系统宽频带振荡研究综述[J]. 中国电机工程学报, 2021, 41(7): 2297-2309.
CHEN L J, XU S Y, SUN H D, et al.A survey on wide-frequency oscillation for power systems with high penetration of power electronics[J]. Proceedings of the CSEE, 2021, 41(7): 2297-2309.
[4] 郝晓弘, 胡开伟, 裴婷婷, 等. 风电接入交直流混联电网外送消纳能力研究[J]. 太阳能学报, 2021, 42(10): 195-201.
HAO X H, HU K W, PEI T T, et al.Study on transmit capacity of wind power connected to AC/DC hybrid transmssion grid[J]. Acta energiae solaris sinica, 2021, 42(10): 195-201.
[5] 张放, 刘军, 李佳欣, 等. 基于同步相量轨迹拟合的电力系统次同步/超同步振荡的实时参数辨识[J]. 中国电机工程学报, 2023, 43(4): 1413-1425.
ZHANG F, LIU J, LI J X, et al.Real-time parameter identification with synchrophasor trajectory fitting technique for subsynchronous/supersynchronous oscillations in power systems[J]. Proceedings of the CSEE, 2023, 43(4): 1413-1425.
[6] 赵峰, 吴梦娣. EEMD-RobustICA和Prony算法在电力系统低频振荡模态辨识中的应用[J]. 太阳能学报, 2019, 40(10): 2919-2929.
ZHAO F, WU M D.Application of EEMD-RobustICA and Prony algorithm in modes identification of power system low frequency oscillation[J]. Acta energiae solaris sinica, 2019, 40(10): 2919-2929.
[7] ZHANG Q,LI F,JIANG Y,et al.Comprehensive control strategy for improving low voltage ride through capability of permanent magnet synchronous generator[J]. Power system protection and control, 2017, 45(6): 62-67.
[8] 李鹏瀚, 王杰, 吴飞. 双馈风电机组次同步控制相互作用的反馈线性化滑模变结构抑制[J]. 电工技术学报, 2019, 34(17): 3661-3671.
LI P H, WANG J, WU F.Sub-synchronous control interaction mitigation for DFIGs by sliding mode control strategy based on feedback linearization[J]. Transactions of China Electrotechnical Society, 2019, 34(17): 3661-3671.
[9] 谢小荣, 刘华坤, 贺静波, 等. 直驱风电机组风电场与交流电网相互作用引发次同步振荡的机理与特性分析[J]. 中国电机工程学报, 2016, 36(9): 2366-2372.
XIE X R, LIU H K, HE J B, et al.Mechanism and characteristics of subsynchronous oscillation caused by the interaction between full-converter wind turbines and AC systems[J]. Proceedings of the CSEE, 2016, 36(9): 2366-2372.
[10] 王杨, 杨汉芦, 肖先勇, 等. 双馈风电机组附加次同步阻尼控制器抑制方法分析与优化设计[J]. 电力自动化设备, 2022, 42(8): 184-190.
WANG Y, YANG H L, XIAO X Y, et al.Mitigation method analysis and optimization design of doubly-fed induction generator additional subsynchronous damping controller[J]. Electric power automation equipment, 2022, 42(8): 184-190.
[11] 吴熙, 徐珊珊, 冯双, 等. 基于改进自适应陷波的双馈风电场时变次同步振荡抑制策略[J]. 中国电机工程学报, 2024, 44(5): 1836-1847.
WU X, XU S S, FENG S, et al.Time-varying subsynchronous oscillation mitigation strategy for DFIG wind farms based on improved adaptive notch filter[J]. Proceedings of the CSEE, 2024, 44(5): 1836-1847.
[12] 张育硕, 郝丽丽, 周彦彤, 等. 风火打捆经串补外送系统次同步振荡分析及抑制策略研究[J]. 电力电容器与无功补偿, 2019, 40(6): 189-195.
ZHANG Y S, HAO L L, ZHOU Y T, et al.Analysis and suppression strategy of sub-synchronous oscillation for wind-thermal-bundled power transmitted by series-compensated system[J]. Power capacitor & reactive power compensation, 2019, 40(6): 189-195.
[13] LIU H K, XIE X R, LI Y, et al.Mitigation of SSR by embedding subsynchronous Notch filters into DFIG converter controllers[J]. IET generation, transmission & distribution, 2017, 11(11): 2888-2896.
[14] MAN J F, CHEN L, TERZIJA V, et al.Mitigating high-frequency resonance in MMC-HVDC systems using adaptive Notch filters[J]. IEEE transactions on power systems, 2022, 37(3): 2086-2096.
[15] 栗然, 卢云, 刘会兰, 等. 双馈风电场经串补并网引起次同步振荡机理分析[J]. 电网技术, 2013, 37(11): 3073-3079.
LI R, LU Y, LIU H L, et al.Mechanism analysis on subsynchronous oscillation caused by grid-integration of doubly fed wind power generation system via series compensation[J]. Power system technology, 2013, 37(11): 3073-3079.
[16] 孙东阳, 孟繁易, 王南, 等. 基于反步自适应准谐振控制的双馈风电机组次同步振荡抑制策略[J]. 电工技术学报, 2023, 38(9): 2375-2390, 2434.
SUN D Y, MENG F Y, WANG N, et al.DFIG sub-synchronous oscillation suppression strategy based on backstepping adaptive quasi-resonant control[J]. Transactions of China Electrotechnical Society, 2023, 38(9): 2375-2390, 2434.
[17] 张剑, 肖湘宁, 高本锋, 等. 双馈风力发电机的次同步控制相互作用机理与特性研究[J]. 电工技术学报, 2013, 28(12): 142-149, 159.
ZHANG J, XIAO X N, GAO B F, et al.Mechanism and characteristic study on sub-synchronous control interaction of a DFIG-based wind-power generator[J]. Transactions of China Electrotechnical Society, 2013, 28(12): 142-149, 159.
[18] 韩应生, 孙海顺, 秦世耀, 等. 电压源型双馈风电并网系统小扰动低频稳定性分析[J]. 电工技术学报, 2023, 38(5): 1312-1324, 1374.
HAN Y S, SUN H S, QIN S Y, et al.Low-frequency stability analysis of voltage-sourced doubly-fed wind power grid-connected system under small disturbance[J]. Transactions of China Electrotechnical Society, 2023, 38(5): 1312-1324, 1374.
[19] 刘其辉, 洪晨威, 逄思敏, 等. 基于弹性系数的双馈风电机组控制参数对次同步振荡作用分析及调整方法[J]. 电工技术学报, 2022, 37(14): 3528-3541.
LIU Q H, HONG C W, PANG S M, et al.Analysis and adjustment method of doubly-fed fan control parameters on subsynchronous oscillation based on impedance elastic sensitivity[J]. Transactions of China Electrotechnical Society, 2022, 37(14): 3528-3541.
[20] 王洋, 杜文娟, 王海风. 风电并网系统次同步振荡频率漂移问题[J]. 电工技术学报, 2020, 35(1): 146-157.
WANG Y, DU W J, WANG H F.Frequency drift of sub-synchronous oscillation in wind turbine generator integrated power system[J]. Transactions of China Electrotechnical Society, 2020, 35(1): 146-157.
[21] 徐衍会, 成蕴丹, 刘慧, 等. 基于瞬时功率的次同步振荡频率提取及振荡源识别方法[J]. 电工技术学报, 2023, 38(11): 2894-2907.
XU Y H,CHENG Y D,LIU H,et al.Sub-synchronous oscillation frequency extraction and oscillation source identification method based on instantaneous power[J].Transactions of China Electrotechnical Society,2023,38(11): 2894-2907.
[22] XIE X R, ZHANG X, LIU H K, et al.Characteristic analysis of subsynchronous resonance in practical wind farms connected to series-compensated transmissions[J]. IEEE transactions on energy conversion, 2017, 32(3): 1117-1126.
[23] CHEN J J, TAN J H, CHANG C H, et al.A new cost-aware sensitivity-driven algorithm for the design of FIR filters[J]. IEEE transactions on circuits and systems Ⅰ: regular papers, 2017, 64(6): 1588-1598.
[24] GU C, ZHAO J X, XU W, et al.Design of linear-phase notch filters based on the OMP scheme and the Chebyshev window[J]. IEEE transactions on circuits and systems Ⅱ: express briefs, 2012, 59(9): 592-596.
[25] XU W, ZHAO J X, GU C.Design of linear-phase FIR multiple-notch filters via an iterative reweighted OMP scheme[J]. IEEE transactions on circuits and systems Ⅱ: express briefs, 2014, 61(10): 813-817.
[26] ICHIGE K, IWAKI M, ISHII R.Accurate estimation of minimum filter length for optimum FIR digital filters[J]. IEEE transactions on circuits and systems Ⅱ: analog and digital signal processing, 2000, 47(10): 1008-1016.
[27] MAILHE B, GRIBONVAL R, BIMBOT F, et al.A low complexity Orthogonal Matching Pursuit for sparse signal approximation with shift-invariant dictionaries[C]//2009 IEEE International Conference on Acoustics, Speech and Signal Processing. Taipei, China, 2009: 3445-3448.
[28] VARMA R K, MOHARANA A.SSR in double-cage induction generator-based wind farm connected to series-compensated transmission line[J]. IEEE transactions on power systems, 2013, 28(3): 2573-2583.
[29] 刘其辉, 田若菡, 贾瑞媛, 等. 基于模糊控制的双馈风电机组次同步振荡自适应抑制策略[J]. 太阳能学报, 2023, 44(7): 392-401.
LIU Q H, TIAN R H, JIA R Y, et al.Adaptive subsynchronous oscillation suppression strategy of double-fed wind power generator based on fuzzy control[J]. Acta energiae solaris sinica, 2023, 44(7): 392-401.

基金

国家自然科学基金(52277100)

PDF(4040 KB)

Accesses

Citation

Detail

段落导航
相关文章

/