一种高性能并网逆变器的控制策略研究

张涛, 苏建徽, 杨向真

太阳能学报 ›› 2025, Vol. 46 ›› Issue (1) : 449-459.

PDF(3342 KB)
欢迎访问《太阳能学报》官方网站,今天是
PDF(3342 KB)
太阳能学报 ›› 2025, Vol. 46 ›› Issue (1) : 449-459. DOI: 10.19912/j.0254-0096.tynxb.2023-1450

一种高性能并网逆变器的控制策略研究

  • 张涛1,2, 苏建徽1,2, 杨向真1,2
作者信息 +

RESEARCH ON A CONTROL STRATEGY OF HIGH-PERFORMANCE GRID-CONNECTED INVERTERS

  • Zhang Tao1,2, Su Jianhui1,2, Yang Xiangzhen1,2
Author information +
文章历史 +

摘要

针对传统并网逆变器控制系统存在静差和富含背景谐波的非理想电网电压下网侧电流质量不高等问题,提出一种高性能并网逆变器的控制策略。首先采用反Park变换(IPT)方法构造网侧电流正交分量,然后在dq旋转坐标系下建立网侧电流控制环路,再选用PI控制器实现电流无差跟踪。为了解决并网电流的谐波问题,引入多谐振控制器,抑制并网电流的低次谐波。在静止坐标系下推导并网逆变器控制系统的数学模型,提出控制系统中PI控制器和多谐振控制器参数的简化设计方法,分析所提控制系统的鲁棒性;最后,针对6 kW单相LCL型并网逆变器控制系统,通过仿真和实验验证所提控制策略的正确性和有效性。

Abstract

Some problems such as a steady state error in the control system, low quality current in grid side under non ideal grid voltage with background harmonics. In order to solve those problems, a control strategy of high-performance grid-connected inverter is pointed out in this paper. Firstly, the inverse Park Transformation (IPT) method is used to construct the orthogonal component of the grid-side current, and then the grid-side current control loop is established under the dq rotating coordinate system, and then a PI controller is used to achieve seamless tracking of the current. In order to solve the harmonic problem of grid current, a multi-resonance controller is introduced to suppress the low-order harmonics of grid-connected current. The mathematical model of the grid-connected inverter control system is derived under the stationary coordinate system, and a simplified design method for the parameters of the PI controller and multi-resonance controller in the control system is proposed. The robustness of the proposed control system is analyzed. Finally, for the 6 kW single-phase LCL grid-connected inverter control system, the correctness and effectiveness of the proposed control strategy are verified through simulation and experiments.

关键词

并网逆变器 / 正交分量构造 / 多谐振控制器 / 参数设计 / 电容电流反馈

Key words

grid-connected inverters / orthogonal component construction / multi-resonant controller / parameter design / capacitor current feedback

引用本文

导出引用
张涛, 苏建徽, 杨向真. 一种高性能并网逆变器的控制策略研究[J]. 太阳能学报. 2025, 46(1): 449-459 https://doi.org/10.19912/j.0254-0096.tynxb.2023-1450
Zhang Tao, Su Jianhui, Yang Xiangzhen. RESEARCH ON A CONTROL STRATEGY OF HIGH-PERFORMANCE GRID-CONNECTED INVERTERS[J]. Acta Energiae Solaris Sinica. 2025, 46(1): 449-459 https://doi.org/10.19912/j.0254-0096.tynxb.2023-1450
中图分类号: TM461   

参考文献

[1] 蔡旭, 李睿, 李征. 储能功率变换与并网技术[M]. 北京: 科学出版社, 2019.
CAI X, LI R, LI Z.Battery energy storage power conversion and grid connection technology[M]. Beijing: Science Press, 2019.
[2] 张兴, 曹仁贤. 太阳能光伏并网发电及其逆变控制[M]. 2版. 北京: 机械工业出版社, 2018.
ZHANG X, CAO R X.Solar photovoltaic grid-connected power generation and its inverter control[M]. 2nd ed. Beijing: China Machine Press, 2018.
[3] 阮新波, 王学华, 潘冬华, 等. LCL型并网逆变器的控制技术[M]. 北京: 科学出版社, 2015: 5-11.
RUAN X B, WANG X H, PAN D H, et al.Control techniques for LCL-type grid-connected inverters[M]. Beijing: Science Press, 2015: 5-11.
[4] 刘芳, 张喆, 马铭遥, 等. 弱电网条件下基于稳定域和谐波交互的并网逆变器LCL参数设计[J]. 中国电机工程学报, 2019, 39(14): 4231-4242.
LIU F, ZHANG Z, MA M Y, et al.LCL filter design method based on stability region and harmonic interaction for grid-connected inverters in weak grid[J]. Proceedings of the CSEE, 2019, 39(14): 4231-4242.
[5] PEÑA-ALZOLA R, LISERRE M, BLAABJERG F, et al. Analysis of the passive damping losses in LCL-filter-based grid converters[J]. IEEE transactions on power electronics, 2013, 28(6): 2642-2646.
[6] XIN Z, MATTAVELLI P, YAO W L, et al.Mitigation of grid-current distortion for LCL-filtered voltage-source inverter with inverter-current feedback control[J]. IEEE transactions on power electronics, 2018, 33(7): 6248-6261.
[7] 鲍陈磊, 阮新波, 王学华, 等. 基于PI调节器和电容电流反馈有源阻尼的LCL型并网逆变器闭环参数设计[J]. 中国电机工程学报, 2012, 32(25): 133-142, 19.
BAO C L, RUAN X B, WANG X H, et al.Design of grid-connected inverters with LCL filter based on PI regulator and capacitor current feedback active damping[J]. Proceedings of the CSEE, 2012, 32(25): 133-142, 19.
[8] 杨明, 宋明洋, 张国澎, 等. LCL型并网逆变器新型电容电压有源阻尼策略[J]. 太阳能学报, 2023, 44(2): 399-408.
YANG M, SONG M Y, ZHANG G P, et al.New type capacittive voltage active damping strategy for LCL grid-connected inverter[J]. Acta energiae solaris sinica, 2023, 44(2): 399-408.
[9] YAN Q Z, WU X J, YUAN X B, et al.An improved grid-voltage feedforward strategy for high-power three-phase grid-connected inverters based on the simplified repetitive predictor[J]. IEEE transactions on power electronics, 2016, 31(5): 3880-3897.
[10] BOSCH S, STAIGER J, STEINHART H.Predictive current control for an active power filter with LCL-filter[J]. IEEE transactions on industrial electronics, 2018, 65(6): 4943-4952.
[11] PAN D H, RUAN X B, BAO C L, et al.Capacitor-current-feedback active damping with reduced computation delay for improving robustness of LCL-type grid-connected inverter[J]. IEEE transactions on power electronics, 2014, 29(7): 3414-3427.
[12] XIN Z, WANG X F, LOH P C, et al.Grid-current-feedback control for LCL-filtered grid converters with enhanced stability[J]. IEEE transactions on power electronics, 2017, 32(4): 3216-3228.
[13] ZHOU S Z, ZHANG Y, LIU Z, et al.Implementation of cross-coupling terms in proportional-resonant current control schemes for improving current tracking performance[J]. IEEE transactions on power electronics, 2021, 36(11): 13248-13260.
[14] ROSHAN A, BURGOS R, BAISDEN A C, et al.A D-Q frame controller for a full-bridge single phase inverter used in small distributed power generation systems[C]//APEC 07-Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition. Anaheim, CA, USA, 2007: 641-647.
[15] 宋崇辉, 徐涛, 王振环, 等. 单相逆变电源电压双闭环矢量控制方法[J]. 电工技术学报, 2019, 34(16): 3386-3395.
SONG C H, XU T, WANG Z H, et al.A vector control method of the single-phase inverter power supply based on voltage double closed-loop[J]. Transactions of China Electrotechnical Society, 2019, 34(16): 3386-3395.
[16] MONFARED M, GOLESTAN S, GUERRERO J M.Analysis, design, and experimental verification of a synchronous reference frame voltage control for single-phase inverters[J]. IEEE transactions on industrial electronics, 2014, 61(1): 258-269.
[17] GOLESTAN S, MONFARED M, FREIJEDO F D, et al.Dynamics assessment of advanced single-phase PLL structures[J]. IEEE transactions on industrial electronics, 2013, 60(6): 2167-2177.
[18] CASTILLA M, MIRET J, MATAS J, et al.Control design guidelines for single-phase grid-connected photovoltaic inverters with damped resonant harmonic compensators[J]. IEEE transactions on industrial electronics, 2009, 56(11): 4492-4501.
[19] 李玉东, 黄鑫, 夏梓豪, 等. 基于PIR的并网逆变器低频次谐波抑制策略研究[J]. 太阳能学报, 2022, 43(12): 32-40.
LI Y D, HUANG X, XIA Z H, et al.Research on suppression strategy of low frequency subharmonics of grid-connected inverter based on PIR[J]. Acta energiae solaris sinica, 2022, 43(12): 32-40.
[20] WANG X H, RUAN X B, LIU S W, et al.Full feedforward of grid voltage for grid-connected inverter with LCL filter to suppress current distortion due to grid voltage harmonics[J]. IEEE transactions on power electronics, 2010, 25(12): 3119-3127.
[21] ZHENG Z S, ZHANG L, WANG Y M, et al.Full grid voltage feedforward for critical mode LCL-type single-phase grid-tied inverters with physical interpretations[J]. IEEE transactions on power electronics, 2023, 38(4): 5283-5295.
[22] WANG C, WANG X H, HE Y Y, et al.A passivity-based weighted proportional-derivative feedforward scheme for grid-connected inverters with enhanced harmonic rejection ability[J]. IEEE journal of emerging and selected topics in power electronics, 2023, 11(4): 3656-3668.
[23] HE Y Y, WANG X H, RUAN X B, et al.Hybrid active damping combining capacitor current feedback and point of common coupling voltage feedforward for LCL-type grid-connected inverter[J]. IEEE transactions on power electronics, 2021, 36(2): 2373-2383.
[24] ZHANG H, RUAN X B, LIN Z H, et al.Capacitor voltage full feedback scheme for LCL-type grid-connected inverter to suppress current distortion due to grid voltage harmonics[J]. IEEE transactions on power electronics, 2021, 36(3): 2996-3006.
[25] ZMOOD D N, HOLMES D G, BODE G H.Frequency-domain analysis of three-phase linear current regulators[J]. IEEE transactions on industry applications, 2001, 37(2): 601-610.
[26] 丁欣, 施睿清, 薛睿南, 等. 弱电网下LCL型单相并网逆变器的鲁棒延时补偿策略[J]. 太阳能学报, 2023, 44(5): 162-170.
DING X, SHI R Q, XUE R N, et al.Robust delay compensation stategy for LCL single-phase grid-connected inverter under weak grid[J]. Acta energiae solaris sinica, 2023, 44(5): 162-170.

基金

国家重点研发计划(2021YFB2601402)

PDF(3342 KB)

Accesses

Citation

Detail

段落导航
相关文章

/