STABILITY ANALYSIS AND IMPROVEMENT METHOD OF WIND FARM GRID-CONNECTED SYSTEM VIA MMC-HVDC CONSIDERING LINK DELAY

Li Hui, Wu You, Xie Xiangjie, Li Qinghe, Tan Hongtao, Zheng Jie

Acta Energiae Solaris Sinica ›› 2022, Vol. 43 ›› Issue (8) : 323-333.

PDF(2113 KB)
Welcome to visit Acta Energiae Solaris Sinica, Today is
PDF(2113 KB)
Acta Energiae Solaris Sinica ›› 2022, Vol. 43 ›› Issue (8) : 323-333. DOI: 10.19912/j.0254-0096.tynxb.2020-1409

STABILITY ANALYSIS AND IMPROVEMENT METHOD OF WIND FARM GRID-CONNECTED SYSTEM VIA MMC-HVDC CONSIDERING LINK DELAY

  • Li Hui1, Wu You1, Xie Xiangjie1, Li Qinghe1, Tan Hongtao1, Zheng Jie1,2
Author information +
History +

Abstract

The double closed-loop control structure of flexible DC converter station is easy to cause link delay and lead to system instability. Based on the small-signal stability analysis, a stability improvement strategy based on the optimization of particle swarm optimization(PSO) algorithm controller parameters is proposed. At first, the detailed state-space model of 68 order system in d-q synchronous reference frame is established, which is validated by the time domain simulation. Secondly, the influence of link delay on system stability is analyzed based on eigenvalue analysis, the characteristic of system stability affected by the link delay of the double closed-loop controller parameter at the wind farm side modular multilevel converter(WFMMC) is obtained, and the participation factor analysis is adopted to filter out the controller parameters related to the stability of the system. Finally, taking the damping ratio and the distance from the characteristic root to the imaginary axis as the optimization goals, a stability improvement strategy based on the improved PSO algorithm is proposed. The results indicate that the stability model and the stability improvement method is effective, and in the case of a long link delay, the stability improvement effect is more significant.

Key words

offshore wind farm / modular multilevel converter / state-space model / system link delay / mode identification / particle swarm optimization

Cite this article

Download Citations
Li Hui, Wu You, Xie Xiangjie, Li Qinghe, Tan Hongtao, Zheng Jie. STABILITY ANALYSIS AND IMPROVEMENT METHOD OF WIND FARM GRID-CONNECTED SYSTEM VIA MMC-HVDC CONSIDERING LINK DELAY[J]. Acta Energiae Solaris Sinica. 2022, 43(8): 323-333 https://doi.org/10.19912/j.0254-0096.tynxb.2020-1409

References

[1] 辛业春, 王威儒, 李国庆. 海上风电MMC-HVDC联网系统控制策略[J]. 太阳能学报, 2019, 40(6): 1731-1738.
XIN Y C, WANG W R, LI G Q.Control strategy on grid connected offshore wind farm based on MMC-HVDC[J]. Acta energiae solaris sinica, 2019, 40(6): 1731-1738.
[2] 郭琦, 郭海平, 黄立滨. 电网电压前馈对柔性直流输电在弱电网下的稳定性影响[J]. 电力系统自动化, 2018, 42(14): 139-144.
GUO Q, GUO H P, HUANG L B.Effect of grid voltage feedforward on VSC-HVDC stability in weak power grid[J]. Automation of electric power systems, 2018, 42(14): 139-144.
[3] 郭贤珊, 刘斌, 梅红明. 渝鄂直流背靠背联网工程交直流系统谐振分析与抑制[J]. 电力系统自动化, 2020, 44(20): 157-167.
GUO X S, LIU B, MEI H M.Analysis and suppression of resonance between AC and DC systems in Chongqing-Hubei back-to-back HVDC project of China[J]. Automation of electric power systems, 2020, 44(20): 157-167.
[4] LYU J, CAI X, MOLINAS M.Frequency domain stability analysis of MMC-Based HVDC for wind farm integration[J]. IEEE journal of emerging and selected topics in power electronics, 2016, 4(1): 141-151.
[5] 郭春义, 崔鹏, 郑安然, 等. 串联混合型直流输电系统的小信号模型及其稳定性研究[J]. 中国电机工程学报, 2021, 41(16): 5569-5580.
GUO C Y, CUI P, ZHENG A R, et al.Small signal model and stability analysis for series connected hybrid HVDC system[J]. Proceedings of the CSEE, 2021, 41(16): 5569-5580.
[6] 苑宾, 许建中, 赵成勇, 等. 利用虚拟电阻提高接入弱交流电网的MMC小信号稳定性控制方法[J]. 中国电机工程学报, 2015, 35(15): 3794-3802.
YUAN B, XU J Z, ZHAO C Y, et al.A virtual resistor based control strategy for enhancing the small-signal stability of MMC integrated in weak AC system[J]. Proceedings of the CSEE, 2015, 35(15): 3794-3802.
[7] 黄方能, 韦超, 周剑, 等. 基于谐波状态空间模型的MMC系统高频振荡分析[J]. 电网技术, 2021, 45(5):1967-1976.
HUANG F N, WEI C, ZHOU J, et al.Analysis of high frequency resonance of MMC system based on harmonic state space model[J]. Power system technology, 2021, 45(5): 1967-1976.
[8] 李探, ANIRUDDHA M G, 赵成勇. 考虑内部动态特性的模块化多电平换流器小信号模型[J]. 中国电机工程学报, 2016, 36(11): 2890-2899.
LI T, ANIRUDDHA M G, ZHAO C Y.Small-signal model of the modular multilevel converter considering the internal dynamics[J]. Proceedings of the CSEE, 2016, 36(11): 2890-2899.
[9] 裴继坤. 直驱永磁风机经柔性直流输电并网的小干扰稳定性分析[D]. 北京: 华北电力大学, 2019.
PEI J K.Small signal stability analysis of grid-connected D-PMSG via VSC-HVDC system[D]. Beijing: North China Electric Power University, 2019.
[10] 郭春义, 彭意, 徐李清. 考虑延时影响的MMC-HVDC系统高频振荡机理分析[J]. 电力系统自动化, 2020, 44(22): 119-126.
GUO C Y, PENG Y, XU L Q.Analysis on high-frequency oscillation mechanism for MMC-HVDC system considering influence of time delay[J]. Automation of electric power systems, 2020, 44(22): 119-126.
[11] 蔡昌春, 邓立华, 江冰, 等. 基于PSO-RBF神经网络的微电网等效建模[J]. 太阳能学报, 2016, 37(1): 76-83.
CAI C C, DENG L H, JIANG B, et al.Micro-grid dynamic equivalent modeling based on PSO and RBF artificial neural network[J]. Acta energiae solaris sinica, 2016, 37(1): 76-83.
[12] 黄智达, 李德波. 基于DESAPSO混合算法的MMC-HVDC系统控制参数优化[J]. 水电能源科学, 2018, 36(12): 192-196.
HUANG Z D, LI D B.Control parameter optimization of MMC-HVDC system based on DESAPSO hybrid algorithm[J]. Water resources and power, 2018, 36(12): 192-196.
PDF(2113 KB)

Accesses

Citation

Detail

Sections
Recommended

/