ENERGY EFFICYENCY ANALYSYS OF AIR ENERGY WATER HEATER IN COLD AREA IN WINTER

Zhang Zhigang, Liu Ying, Yao Wanxiang

Acta Energiae Solaris Sinica ›› 2023, Vol. 44 ›› Issue (1) : 543-550.

PDF(1959 KB)
Welcome to visit Acta Energiae Solaris Sinica, Today is
PDF(1959 KB)
Acta Energiae Solaris Sinica ›› 2023, Vol. 44 ›› Issue (1) : 543-550. DOI: 10.19912/j.0254-0096.tynxb.2021-0981

ENERGY EFFICYENCY ANALYSYS OF AIR ENERGY WATER HEATER IN COLD AREA IN WINTER

  • Zhang Zhigang1, Liu Ying1, Yao Wanxiang2,3
Author information +
History +

Abstract

The performance of a small household air source heat pump water heater was tested in winter, and the performance changes of the unit were studied when the outdoor air temperature and water tank temperature were different. Based on the test data, the sensitive factors affecting the unit performance are analyzed,and the average energy efficiency in winter is analyzed according to the measured data in Tianjin. The results show that the lowest COP is 1.30, which has energy-saving effect, under the condition of ensuring water comfort and stable operation of the unit, 45 ℃ is the best set temperature of the water tank. The outdoor air temperature offset is more sensitive to the system performance than the average temperature offset of the water tank. Under the test conditions,there is little difference in the average energy efficiency of the whole winter when the heat pump unit works alone and starts the electric auxiliary heating.If the user sets the unit to start heating at the highest temperature of the day,better energy-saving effect can be obtained.

Key words

efficiency analysis / air source heat pump / water heater / ambient temperature / cold area

Cite this article

Download Citations
Zhang Zhigang, Liu Ying, Yao Wanxiang. ENERGY EFFICYENCY ANALYSYS OF AIR ENERGY WATER HEATER IN COLD AREA IN WINTER[J]. Acta Energiae Solaris Sinica. 2023, 44(1): 543-550 https://doi.org/10.19912/j.0254-0096.tynxb.2021-0981

References

[1] CHAO H, WANG F H, LI S T, et al.A performance comparison of serial and parallel solar-assisted heat pump heating systems in Xi’an, China[J]. Energy science & engineering, 2019, 7(4): 1379-1393.
[2] CHOI Y J, RYO Z O, YU J N.Impact of long-term operation of ground-source heat pump on subsurface thermal state in urban areas[J]. Sustainable cities & society, 2018, 38: 429-439.
[3] NALDI C, MORINI G L, ZANCHINI E.A method for the choice of the optimal balance-point temperature of air-to-water heat pumps for heating[J]. Sustainable cities & society, 2014, 12: 85-91.
[4] ZHENG X J, SHI R, YOU S J, et al.Experimental study of defrosting control method based on image processing technology for air source heat pumps[J]. Sustainable cities & society, 2019, 51: 101667.
[5] 张丽, 李征涛, 余鹏, 等. 空气源热泵热水器的性能分析[J]. 能源工程, 2018(1): 77-80.
ZHANG L, LI Z T, YU P, et al.Performance analysis of air source heat pump water heater[J]. Energy engineering, 2018(1): 77-80.
[6] 郝吉波, 王志华, 姜宇光, 等. 空气源热泵热水器系统性能分析[J]. 制冷与空调, 2013, 13(1): 59-62, 58.
HAO J B, WANG Z H, JIANG Y G, etal. Analysis of system performance of air source heat pump water heater[J]. Refrigeration and air-conditioning, 2013, 13(1): 59-62, 58.
[7] 王宇, 由世俊, 孙颖楷, 等. 空气源热泵热水器性能测试及运行评价研究[J]. 流体机械, 2017, 45(10): 77-82.
WANG Y, YOU S J, SUN Y K, et al.Performance test investigation and operational evaluation of air source heat pump water heater[J]. Fluid machinery, 2017, 45(10): 77-82.
[8] 郭兴国, 敖宇强, 刘向伟. 夏热冬冷和夏热冬暖地区家用空气能热水器的经济性分析[J]. 流体机械, 2019, 47(7): 80-84, 71.
GUO X G, AO Y Q, LIU X W.The economic analysis of air energy water heater for household purpose in hot summer and cold winter and hot summer and warm winter areas[J]. Fluid machinery, 2019, 47(7): 80-84, 71.
[9] 杨庆成, 施永康, 招就权, 等. 室外工况对空气源热泵热水器性能的影响[J]. 制冷与空调, 2020, 20(10): 67-72.
YANG Q C, SHI Y K, ZHAO J Q, et al.Impact of ambient conditions on performance of air source heat pump water heater[J]. Refrigeration and air-conditioning, 2020, 20(10): 67-72.
[10] 王伟, 倪龙, 马最良. 空气源热泵技术与应用[M]. 北京: 中国建筑工业出版社, 2017: 21-23.
WANG W, NI L, MA Z L.Air source heat pump technology and application[M]. Beijing: China Construction Industry Press, 2017: 21-23.
[11] 张辉, 韩啸霖, 弓南, 等. 高层住宅被动式节能设计因素敏感性分析[J]. 建筑节能, 2021, 49(3): 13-18.
ZHANG H, HAN X L, GONG N, et al.Sensitivity analysis of passive energy-saving design factors of high-rise residential buildings[J]. Journal of building energy efficiency, 2021, 49(3): 13-18.