Abstract

This paper presents an investigation on the solar cascade ejector system with cold and heat storage using the refrigerant R290/CO2.The advanced exergy analysis method is utilized to analyze the interactions and optimization potential among the system components, and the effects of ejector component efficiency and CO2 side pressure of intermediate heat exchanger on system exergy performance are discussed. The R290 ejector has the largest avoidable endogenous exergy destruction and the highest potential for improvement, according to advanced exergy study results. Endogenous destruction accounts for 89.82% of the system exergy destruction, whereas the avoidable destruction accounts for 42.14%. The exergy efficiency of system can be effectively improved by increasing the ejector efficiency. There exists an optimal intermediate heat exchanger pressure to maximize exergy efficiency of system and minimize the avoidable endogenous exergy destruction of the R290 ejector.

Key words

solar energy / exergy / cascade system / advanced exergy analysis

Cite this article

Download Citations
Mi Changning, Zheng Lixing, Hu Hongwei, Xiong Yingying. STUDY ON OPTIMIZATION POTENTIAL OF SOLAR CASCADE EJECTOR SYSTEM WITH COLD AND HEAT STORAGE[J]. Acta Energiae Solaris Sinica. 2023, 44(8): 362-366 https://doi.org/10.19912/j.0254-0096.tynxb.2022-0611

References

[1] BRAIMAKIS K.Solar ejector cooling systems: a review[J]. Renewable energy, 2021, 164: 566-602.
[2] GIL B, KASPERSKI J.Performance analysis of a solar-powered ejector air-conditioning cycle with heavier hydrocarbons as refrigerants[J]. Energy procedia, 2014, 57: 2619-2628.
[3] BELLOS E, TZIVANIDIS C.Optimum design of a solar ejector refrigeration system for various operating scenarios[J]. Energy conversion and management, 2017, 154: 11-24.
[4] AGHAZIARATI Z, AGHDAM A H.Thermoeconomic analysis of a novel combined cooling, heating and power system based on solar organic Rankine cycle and cascade refrigeration cycle[J]. Renewable energy, 2021, 164: 1267-1283.
[5] GADO M G, MEGAHED T F, OOKAWARA S, et al.Potential application of cascade adsorption-vapor compression refrigeration system powered by photovoltaic/thermal collectors[J]. Applied thermal engineering, 2022, 207: 118075.
[6] PEREZ B P, GUTIERREZ M A, CARRILLO J E, et al.Performance of solar-driven ejector refrigeration system (SERS) as pre-cooling system for air handling units in warm climates[J]. Energy, 2022, 238: 121647.
[7] PARK W Y, SHAH N, VINE E, et al.Ensuring the climate benefits of the Montreal protocol: global governance architecture for cooling efficiency and alternative refrigerants[J]. Energy research & social science, 2021, 76: 102068.
[8] LI H, GONG X F, XU W J, et al.Effects of climate on the solar-powered R1234ze/CO2 cascade cycle for space cooling[J]. Renewable energy, 2020, 153: 870-883.
[9] 王树成, 付忠广, 张高强, 等. 基于先进㶲分析方法的燃气蒸汽联合循环㶲损分析[J]. 热力发电, 2019, 48(3): 75-79, 95.
WANG S C, FU Z G, ZHANG G Q, et al.Exergy destruction analysis of gas-steam combined cycle based on the advanced exergy analysis method[J]. Thermal power generation, 2019, 48(3): 75-79, 95.
[10] TSATSARONIS G, PARK M H.On avoidable and unavoidable exergy destructions and investment costs in thermal systems[J]. Energy conversion and management, 2002, 43(9-12): 1259-1270.
[11] BAI T, YU J L, YAN G.Advanced exergy analyses of an ejector expansion transcritical CO2 refrigeration system[J]. Energy conversion and management, 2016, 126: 850-861.
[12] CHEN J Y, HAVTUN H, PALM B.Conventional and advanced exergy analysis of an ejector refrigeration system[J]. Applied energy, 2015, 144: 139-151.
[13] ZHENG L X, HU Y D, MI C N, et al.Advanced exergy analysis of a CO2 two-phase ejector[J]. Applied thermal engineering, 2022, 209: 118247.
[14] PRIDASAWAS W, LUNDQVIST P.An exergy analysis of a solar-driven ejector refrigeration system[J]. Solar energy, 2004, 76(4): 369-379.
[15] MOROSUK T, TSATSARONIS G.Advanced exergy-based methods used to understand and improve energy-conversion systems[J]. Energy, 2019, 169: 238-246.
[16] MUHAMMAD H A, LEE B, CHO J, et al.Application of advanced exergy analysis for optimizing the design of carbon dioxide pressurization system[J]. Energy, 2021, 228: 120580.
[17] LEMMONN E W,HUBER M L,MCLINDEN M O.Nist standard reference database 23, reference fluid thermodynamic and transport properties (REFPROP).version 9.0[CP/DK]. National institute of standards and technology, 2010.
[18] SARKAR J.Optimization of ejector-expansion transcritical CO2 heat pump cycle[J]. Energy, 2008, 33(9): 1399-1406.