Using the theory of wall thermal system, according to the characteristics of regional differences and surface characteristics differences in the outdoor boundary conditions of wall heat transfer, Lhasa, Yinchuan and Xi'an were selected as representative areas. The equivalent calculation method of the thermal parameters of the outer wall surface was discussed, and the influencing law of the solar radiation absorption coefficient on the energy saving of the south wall and the temperature of the inner wall surface under the heating condition in winter was discussed. The results show that increasing the solar absorptivity of the south wall can effectively increase the energy saving, but it will reduce the stability of the inner wall surface temperature and the fluctuation range of the inner wall surface temperature. This effect is most significant in the Lhasa area with the highest solar radiation intensity, followed by Yinchuan, followed by Xi'an, and with the increase of wall heat transfer resistance and thermal inertia index, the sensitivity of energy saving and inner wall fluctuation to solar absorptivity becomes smaller.
Key words
solar energy /
passive solar heating /
energy saving /
solar absorptivity /
equivalent calculation /
fluctuation range of inner wall temperature
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
References
[1] 董海荣, 祁少明, 麻建锁. 涂料外饰面的太阳辐射吸收性能测试方法分析[J]. 太阳能学报, 2012, 33(9): 1600-1603.
DONG H R, QI S M, MA J S.Analysis on experimental method of coatings’ solar absorbing performance[J]. Acta energiae solaris sinica, 2012, 33(9): 1600-1603.
[2] 张红婴, 钟珂, 刘加平. 太阳辐射吸收系数对围护结构夏季净得热量的影响[J]. 太阳能学报, 2017, 38(1): 156-163.
ZHANG H Y, ZHONG K, LIU J P.The effect of solar absorption coeficient on net heat gain of building envelopes in summer[J]. Acta energiae solaris sinica, 2017, 38(1): 156-163.
[3] 刘加平. 建筑物理[M]. 3版. 北京: 中国建筑工业出版社, 2000.
LIU J P Architectural physics[M]LIU J P Architectural physics[M]. 3rd edition. Beijing: China Architecture & Building Press, 2000.
[4] 张晴原, Joe Huang.中国建筑用标准气象数据库[M]. 北京: 机械工业出版社, 2004.
ZHANG Q Y, HUANG J.China standard meteorological database for buildings[M]. Beijing: China Machine Press, 2004.
[5] 冉茂宇. 隔热涂料用于建筑外表的热工性能等效折算方法[J]. 太阳能学报, 2016, 37(9): 2415-2421.
RAN M Y.Equivalent conversion and calculation method of the thermal performances for thermal insulation coating painted on the exterior surface of building[J]. Acta energiae solaris sinica, 2016, 37(9): 2415-2421.
[6] GB/T 50824—2013, 农村居住建筑节能设计标准[S].
GB/T 50824—2013, energy efficiency design standards for rural residential buildings[S].
[7] JGJ 26—2018, 严寒和寒冷地区居住建筑节能设计标准[S].
JGJ 26—2018, Energy-saving design standards for residential buildings in severe cold and cold regions[S].
[8] 彦启森, 赵庆珠. 建筑热过程[M]. 北京: 中国建筑工业出版社, 1986.
YAN Q S,ZHAO Q Z.Thermal process of building[M]. Beijing: China Architecture & Building Press, 1986.
[9] 冉茂宇. 建筑外表涂层降温热衰减计算及其热工性能评价[J]. 建筑科学, 2019, 35(12): 108-112, 136.
RAN M Y.Thermal decrement calculation and performance evaluation of cooling coatings on the exterior surface of buildings[J]. Building science, 2019, 35(12): 108-112, 136.