A METHOD FOR CALCULATING OPTIMAL INSTALLED CAPACITY OF AIR SOURCE HEAT PUMP COUPLED ELECTRIC BOILER

Zhang Xiaoming, Zhang Haotian, Wang Qiang, Ma Yinghan, Zhao Shiyu

Acta Energiae Solaris Sinica ›› 2024, Vol. 45 ›› Issue (9) : 228-236.

PDF(1457 KB)
Welcome to visit Acta Energiae Solaris Sinica, Today is
PDF(1457 KB)
Acta Energiae Solaris Sinica ›› 2024, Vol. 45 ›› Issue (9) : 228-236. DOI: 10.19912/j.0254-0096.tynxb.2023-0823

A METHOD FOR CALCULATING OPTIMAL INSTALLED CAPACITY OF AIR SOURCE HEAT PUMP COUPLED ELECTRIC BOILER

  • Zhang Xiaoming, Zhang Haotian, Wang Qiang, Ma Yinghan, Zhao Shiyu
Author information +
History +

Abstract

With the promotion of the “self-generation” mode in photovoltaic power generation and the introduction of peak and valley tariff policies, the issue of selecting the economically efficient installed capacity for air source heat pump coupled with electric boiler heating system has become more prominent. In light of this, we propose a method for calculating the installed capacity that takes into account the impacts of PV power generation and peak and off-peak tariffs. We use the optimal unguaranteed days (OGD) of the air source heat pump as the reference value for selection. A new module has been developed by Trnsys to create a system model with automatic optimization capabilities. After verifying the accuracy of the model using test data, we calculate the recommended OGD values for five representative cities based on the model. The results show that the OGD value is influenced by both the building load size and the installed PV capacity. When the average OGD value is used as the recommended value, the maximum error in the annual cost value of a single building corresponding to the average value of OGD is 8.17%. This ensures the accuracy of the calculation. On average, the OGD value decreases by 46.83% with warming in each climate subzone. The maximum OGD value in Beijing is only 5. This suggests that the addition of photovoltaic power generation to such systems in cold B zone cities can be considered without auxiliary heat sources.

Key words

air source heat pumps (ASHP) / simulation model / photovoltaic power generation / optimal installed capacity / TRNSYS

Cite this article

Download Citations
Zhang Xiaoming, Zhang Haotian, Wang Qiang, Ma Yinghan, Zhao Shiyu. A METHOD FOR CALCULATING OPTIMAL INSTALLED CAPACITY OF AIR SOURCE HEAT PUMP COUPLED ELECTRIC BOILER[J]. Acta Energiae Solaris Sinica. 2024, 45(9): 228-236 https://doi.org/10.19912/j.0254-0096.tynxb.2023-0823

References

[1] RAI A, NUNN O.On the impact of increasing penetration of variable renewables on electricity spot price extremes in Australia[J]. Economic analysis and policy, 2020, 67: 67-86.
[2] 郭晓利, 赵莹, 曲楠, 等. 基于满意度的户用型微电网多属性需求响应策略[J]. 太阳能学报, 2021, 42(7): 21-27.
GUO X L, ZHAO Y, QU N, et al.Multi-attribute demand response strategy of household microgrid based on satisfaction[J]. Acta energiae solaris sinica, 2021, 42(7): 21-27.
[3] 孙健, 吴可欣, 王寅武, 等. 夏热冬冷地区新型高温空气源热泵实验研究[J]. 太阳能学报, 2023, 44(6): 186-192.
SUN J, WU K X, WANG Y W, et al.Experimental study on a new high temperature air source heat pump in hot summer and cold winter areas[J]. Acta energiae solaris sinica, 2023, 44(6): 186-192.
[4] KLEIN K, HUCHTEMANN K, MÜLLER D. Numerical study on hybrid heat pump systems in existing buildings[J]. Energy and buildings, 2014, 69: 193-201.
[5] HUANG J R, ZOU T H, LI T, et al.Study on discharging characteristics of solid heat storage bricks: experiment and simulation[J]. Energy reports, 2023, 9: 1948-1962.
[6] DI PERNA C, MAGRI G, GIULIANI G, et al.Experimental assessment and dynamic analysis of a hybrid generator composed of an air source heat pump coupled with a condensing gas boiler in a residential building[J]. Applied thermal engineering, 2015, 76: 86-97.
[7] BAGARELLA G, LAZZARIN R M, LAMANNA B.Cycling losses in refrigeration equipment: an experimental evaluation[J]. International journal of refrigeration, 2013, 36(8): 2111-2118.
[8] ZHANG W L, KLEMEŠ J J, KIM J K.Design and optimisation of dual-mode heat pump systems using natural fluids[J]. Applied thermal engineering, 2012, 43: 109-117.
[9] LI Z Y, WEI W Z, WANG W, et al.A method for sizing air source heat pump considering the joint effect of outdoor air temperature and relative humidity[J]. Journal of building engineering, 2023, 65: 105815.
[10] NIU J D, TIAN Z, LU Y K, et al.A robust optimization model for designing the building cooling source under cooling load uncertainty[J]. Applied energy, 2019, 241: 390-403.
[11] LI H X, WANG S W, XIAO F.Probabilistic optimal design and on-site adaptive commissioning of building air-conditioning systems concerning uncertainties[J]. Energy procedia, 2019, 158: 2725-2730.
[12] T/CECS 564—2018, 空气源热泵供暖工程技术规程[S].
T/CECS 564—2018,Technical specification for air source heat pump heating engineering[S].
[13] 杨少刚. 基于TRNSYS地理管地源热泵变流量系统仿真研究[D]. 济南: 山东建筑大学, 2016.
YANG S G.Simulation study on variable flow system of ground source heat pump based on TRNSYS geographical pipe[D]. Ji'nan: Shandong Jianzhu University, 2016.
PDF(1457 KB)

Accesses

Citation

Detail

Sections
Recommended

/