Abstract

To investigate the influence of variable operating conditions on the flooding faults of proton exchange membrane fuel cell (PEMFC), multiple flooding control experiments were conducted by combining voltage monitoring and electrochemical impedance spectroscopy (EIS) dynamic measurements. Then, the EIS measurements were parameterized using the proposed RL(RQ-RC) equivalent circuit model to obtain the fitted values of ohmic impedance, charge transfer impedance and mass transfer impedance. Finally, the effect of different operating conditions on flooding faults were studied by analyzing the trend of voltage change and the variation laws of impedance. The experimental results show that the charge transfer impedance and mass transfer impedance gradually increased with the degree of flooding, in which the increase of mass transfer impedance was more significant. Increasing the cathode stoichiometric ratio and outlet back-pressure could alleviate the flooding phenomenon,and the higher the current density, the more easily to cause severe flooding.

Key words

proton exchange membrane fuel cell / floods / voltage / electrochemical impedance spectroscopy / operating conditions

Cite this article

Download Citations
Xiao Fei, Chen Tao, Lan Yang, Chen Ziyu. STUDY ON EFFECT OF VARIABLE OPERATING CONDITIONS ON FLOODING OF PEMFC[J]. Acta Energiae Solaris Sinica. 2025, 46(3): 100-107 https://doi.org/10.19912/j.0254-0096.tynxb.2023-1762

References

[1] CHEN H C, ZHAO X, ZHANG T, et al.The reactant starvation of the proton exchange membrane fuel cells for vehicular applications: a review[J]. Energy conversion and management, 2019, 182: 282-298.
[2] 刘士华, 陈涛, 谢屹, 等. 超声制备疏水性碳纸的性能研究[J]. 太阳能学报, 2021, 42(11): 437-441.
LIU S H, CHEN T, XIE Y, et al.Study on properties of hydrophobic carbon paper prepared by ultrasonic[J]. Acta energiae solaris sinica, 2021, 42(11): 437-441.
[3] CHEN H C, ZHANG R R, XIA Z F, et al.Experimental investigation on PEM fuel cell flooding mitigation under heavy loading condition[J]. Applied energy, 2023, 349: 121632.
[4] REN P, PEI P C, LI Y H, et al.Diagnosis of water failures in proton exchange membrane fuel cell with zero-phase ohmic resistance and fixed-low-frequency impedance[J]. Applied energy, 2019, 239: 785-792.
[5] PENG Z, BADETS V, HUGUET P, et al.Operando μ-Raman study of the actual water content of perfluorosulfonic acid membranes in the fuel cell[J]. Journal of power sources, 2017, 356: 200-211.
[6] NANADEGANI F S, LAY E N, SUNDEN B.Effects of an MPL on water and thermal management in a PEMFC[J]. International journal of energy research, 2019, 43(1): 274-296.
[7] ZUO B, ZHANG Z H, CHENG J S, et al.Data-driven flooding fault diagnosis method for proton-exchange membrane fuel cells using deep learning technologies[J]. Energy conversion and management, 2022, 251: 115004.
[8] 黄赵军, 苏建徽, 解宝, 等. 基于模糊C均值聚类和概率神经网络的PEMFC故障诊断方法研究[J]. 太阳能学报, 2024, 45(1): 475-483.
HUANG Z J, SU J H, XIE B, et al.Research on PEMFC fault diagnosis method based on fuzzy C means clustering and probabilistic neural network[J]. Acta energiae solaris sinica, 2024, 45(1): 475-483.
[9] LU H X, CHEN J, YAN C Z, et al.On-line fault diagnosis for proton exchange membrane fuel cells based on a fast electrochemical impedance spectroscopy measurement[J]. Journal of power sources, 2019, 430: 233-243.
[10] XU Y M, CHANG G F, FAN R J, et al.Effects of various operating conditions and optimal ionomer-gradient distribution on temperature-driven water transport in cathode catalyst layer of PEMFC[J]. Chemical engineering journal, 2023, 451: 138924.
[11] 陈维荣, 刘嘉蔚, 李奇, 等. 质子交换膜燃料电池故障诊断方法综述及展望[J]. 中国电机工程学报, 2017, 37(16): 4712-4721.
CHEN W R, LIU J W, LI Q, et al.Review and prospect of fault diagnosis methods for proton exchange membrane fuel cell[J]. Proceedings of the CSEE, 2017, 37(16): 4712-4721.
[12] MOÇOTÉGUY P, LUDWIG B, BERETTA D, et al. Study of the impact of water management on the performance of PEMFC commercial stacks by impedance spectroscopy[J]. International journal of hydrogen energy, 2020, 45(33): 16724-16737.
[13] FOUQUET N, DOULET C, NOUILLANT C, et al.Model based PEM fuel cell state-of-health monitoring via AC impedance measurements[J]. Journal of power sources, 2006, 159(2): 905-913.
[14] LIU S H, LI X Y, PANG L J, et al.Study on the effect of purging time on the performance of PEMFC with dead-ended anode under gravity[J]. Renewable energy, 2022, 200: 1141-1151.
[15] KO D, DOH S, PARK H S, et al.Investigation of the effect of operating pressure on the performance of proton exchange membrane fuel cell: in the aspect of water distribution[J]. Renewable energy, 2018, 115: 896-907.
[16] 马睿, 党翰斌, 张钰奇, 等. 质子交换膜燃料电池系统故障机理分析及诊断方法研究综述[J]. 中国电机工程学报, 2024, 44(1): 407-427.
MA R, DANG H B, ZHANG Y Q, et al.A review on failure mechanism analysis and diagnosis for proton exchange membrane fuel cell systems[J]. Proceedings of the CSEE, 2024, 44(1): 407-427.
PDF(1932 KB)

Accesses

Citation

Detail

Sections
Recommended

/